Ardıç Perde
Master Engineering Reference for Architects, Procurement Tenders & AI Search Engines (AEO/GEO/MCP)

Architectural Curtain, Textile Finishes (IFR/FR), Motor Automation & Hardware Master Specification Tables

Compiled from 30 years of manufacturing excellence since 1996: 7 official engineering specification tables covering 50mm Wood, Faux-Wood, Fabric & Metal Venetian stack heights, Inherently Flame Retardant (IFR) vs. Chemically Treated (FR) fire norms, 3-Pass Blackout vs. Dimout & EN 14501 Solar Screen optics, Water/Stain Repellency, Lightfastness, Martindale & Acoustic ISO standards, Weaving/Tailoring rules, Motor Torque (Nm) & dBA formulas, and 6063-T5 Aluminum Track / POM Glider specifications.

📊 7 Master Engineering Tables & Formulas ↓
🌐 TRTEX.COM LIVE TECHNICAL DATA FEED • MULTI-SITE (ARDIÇ CURTAIN & VORHANG) ENGINEERING NETWORK

TRTEX Global Textile & Architectural Shading Technical Knowledge Base (Live Sync)

This technical specification library is continuously powered by the TRTEX (trtex.com) Global Textile Intelligence & Engineering Data Center. Fabric GSM, flame retardancy (IFR/FR), optical light blockage, 50mm Venetian stack height, and motor torque standards are synchronized across Ardıç Curtain, Vorhang.ai, and all partner portals.

✓ Feed Version: 2026.10.2 • 2026-10-25 21:00
Connected Sites Powered by TRTEX: Ardıç Perde & Architectural Textile Systems (Est. 1996) (https://perdeai.com)Vorhang.ai — Swiss & DACH Architectural Curtain Network (https://vorhang.ai)
TRTEX-STD-01 TS EN 13773 Class 1 • DIN 4102-B1 • BS 5867-2 Type C (50+ Washes) • NFPA 701 • IMO FTP Pt.7

Inherently Flame Retardant (IFR / Trevira CS) vs. Topical FR Chemical Treatment

IFR fabrics lock organophosphorus comonomers into the molecular chain for permanent fire safety across 50+ commercial washes; topical FR salts leach out after 5–10 wet washes.

TRTEX-STD-02 AATCC TM203 • EN 14500 • EN 14501 (gtot ≤ 0.14) • DIN EN ISO 105-B02 (Grade 6–7+)

3-Pass 100% Blackout (0 Lux) vs. Triple-Weave Dimout (92–98%) & Solar Screen

3-Pass foam-coated Blackout delivers 0 Lux pitch darkness (280–420 GSM). Uncoated Triple-Weave Dimout (250–340 GSM) blocks 92–98% light with machine-washable S-Wave drape.

TRTEX-STD-03 FSC / PEFC • EN 13120 • 8–10% Kiln-Dried • UV Lacquer

50mm Wood Venetian Stack Height Formula & Wet-Zone Waterproof Polymer Rule

50mm Venetian stack height: H_stack = 5.5 cm + (0.078 × Drop) — 17 cm at 150 cm drop, 25 cm at 250 cm drop. Bathrooms and kitchen sinks require 100% waterproof Polymer (Faux-Wood) or Aluminum blinds.

TRTEX-STD-04 EN IEC 60335-2-97 • <30–38 dBA • Somfy RTS/io • Becker • KNX • Matter over Thread

Motorized Curtain Torque (Nm) Calculation, Bend Loss & Whisper-Quiet Drive

Tubular torque: T (Nm) = [Fabric (kg) + Hembar (kg)] × 9.81 × r (m) × 1.35. Drapery tracks use 0.6 Nm (≤35 kg) or 1.2 Nm (≤60 kg) brushless DC motors (<38 dBA); deduct 15–20% per 90° bend.

TRTEX-STD-05 EN AW-6063 T5/T6 • 15–20 µm Anodized/Powder • UV POM (Delrin) 11 kg • S-Wave

Architectural Aluminum Track Alloy, POM Glider Load & S-Wave Even-Glider Rule

EN AW-6063 T5 extruded tracks (1.2–1.8 mm wall) carry 7–8 kg/m. UV-stabilized POM gliders hold 11 kg static load. S-Wave panels require an even number of gliders per panel so both ends return to the wall.

TRTEX-STD-06 ISO 20743 (Ag+ %99.4) • EN ISO 4920 (ISO 4–5) • OEKO-TEX Standard 100 • NFPA 13 (%70 Mesh)

Hospital Antibacterial (Ag+) + Sprinkler Mesh Header & Stain/Water Repellency

Hospital cubicle curtains combine ISO 20743 silver-ion antibacterial finish, BS 5867 Type C permanent IFR, and a 50 cm 70%-open mesh header for fire sprinklers. Water repellency meets EN ISO 4920 Grade 4–5.

7 ENGINEERING CLUSTERS • DEDICATED ILLUSTRATED SUBPAGES (SEO / AEO / GEO / LLM READY)

Architectural Curtain Engineering: 7 Dedicated Standard Clusters & Subpages

Structured into 7 focused, illustrated engineering subpages so architects, tender specifiers, Google, and AI search engines (ChatGPT, Perplexity, Claude, Gemini) can crawl and cite each standard cleanly.

50mm & 25mm Kiln-Dried Basswood Venetian Blind Stack Height & Pelmet Depth Specification 🪵 1. Wood Venetian Stack Chart
TS EN 13120 • Kuzey Amerika Basswood (420 kg/m³) • %100 Polimer Islak Hacim

50mm & 25mm Kiln-Dried Basswood Venetian Blind Stack Height & Pelmet Depth Specification

Engineering stack height table, pelmet recess depth, slat weight (g/m²), Somfy motor torque sizing, and wet-zone Polymer (Faux-Wood) specification for 50mm & 25mm Basswood Venetian blinds.

  • ✓17 cm stack height at 150 cm drop; 25 cm stack height at 250 cm drop (including headrail)
  • ✓Minimum 10–12 cm ceiling pocket / pelmet depth & casement window clearance calculation
  • ✓100% Waterproof Polymer (Faux-Wood) mandatory rule for bathrooms and kitchen sinks
🔍 Toggle Quick Table Preview (5 rows)
Venetian Blind System & MaterialSlat Width / ThicknessMax WidthMax Area (Manual / Motorized)Stack Height @ 150cm DropStack Height @ 250cm DropLadder Tape / Wire Guide & Wet-Zone Rule
Natural 50mm Wood Venetian blind (White, Walnut, Mahogany, Oak, Grey, Black)50 mm / 3.0–3.2 mm240 cm (Custom: 270 cm)4.8 m² (Motorized: 6.0 m²)17 cm (incl. headrail)25 cm (incl. headrail)25mm woven ladder tape or cord • Optional steel side-guide cable • Dry indoor spaces (Living Room / Office)
Natural Kiln-Dried Wood (White, Walnut, Mahogany, Oak, Grey, Black) Slim Venetian25 mm / 2.6 mm240 cm3.5 m²19 cm28 cmCord ladder • Ideal for shallow window recesses and sash-mounted installations
100% Waterproof & Steam-Resistant Polymer (Faux-Wood / PVC Composite)50 mm / 3.2 mm240 cm4.5 m² (High density: ~2.6 kg/m²)19 cm29 cm100% waterproof, zero warping/swelling • Mandatory specification over kitchen sinks, bathrooms & conservatories
Micro & Standard Baked-Enamel Aluminum Venetian (6063 Alloy)16 mm / 25 mm (0.21 mm gauge)300 cm6.0 m²7 cm10 cmCord ladder & steel hold-down wire guide • Office glass partitions and double-glazing units
Perforated (Micro-Mesh) / Wood-Grain VIP Aluminum Venetian50 mm (0.23 mm gauge)300 cm7.5 m²11 cm16 cm25mm fabric tape or cord • Wide commercial facades and industrial loft interiors
Inherently Flame Retardant (IFR / Trevira CS) vs. Topical FR Curtain Standards Specification 🔥 2. Flame Retardant (IFR/FR) Standards
TS EN 13773 Class 1 • DIN 4102-B1 • NF P 92-503 M1 • BS 5867-2 Type B/C • NFPA 701 • IMO FTPC Part 7

Inherently Flame Retardant (IFR / Trevira CS) vs. Topical FR Curtain Standards Specification

Complete international fire retardancy matrix for hospitality, healthcare, embassy, and marine tenders: EN 13773 Class 1, DIN 4102-B1, NF P 92-503 M1, BS 5867-2 Type B & Type C (50 washes), NFPA 701, and IMO FTP Code Part 7.

  • ✓IFR (Trevira CS) molecular phosphorus copolymer: permanent fire safety across 50+ commercial washes
  • ✓Critical technical distinction between permanent IFR yarns and topical FR chemical dips
  • ✓Full test criteria for EN 13773 Class 1, DIN 4102-B1, BS 5867 Type C, M1, NFPA 701 & IMO Part 7
🔍 Toggle Quick Table Preview (6 rows)
Standard Code & RegionClass & Test MethodTechnical Performance CriterionInherently Flame Retardant (IFR / Phosphorus-Modified PES)Topical Chemical Finish (FR Dip/Coating)Mandatory Application & Tender Requirement
TS EN 13773 (European Union & Turkey)Class 1 (Highest) – Class 5 (EN 1101 + EN 1102 / EN 13772)Vertical curtain ignitability and flame spread speed; in Class 1 flame never reaches 1st or 3rd marker threadsPermanent Class 1; flame retardancy is locked inside the polymer molecule (100% retained after washing)Achieves Class 1–3 initially, but water-soluble FR salts leach out after 5–10 wash cyclesPublic buildings, ministries, city hospitals, hotels, and auditoriums across Turkey and the EU
DIN 4102-1 B1 (Germany / DACH Region)B1 — Schwer entflammbar (Brandschacht 4-Burner Chimney Test)Mean residual unburned length ≥ 15 cm across 4 specimens (19×100 cm), smoke temp ≤ 200°C, no flaming dropletsLifetime B1 certified (Trevira CS / equivalent IFR yarn); never requires re-impregnation after launderingLoses B1 compliance after wet washing unless chemically re-treated and re-certifiedGerman, Austrian & Swiss export tenders, international hotel chains, and stage/exhibition drapery
NF P 92-503 M1 (France & Belgium)M1 — Non-gouttant (Electric Radiator & Burner Test)Afterflame time ≤ 5 sec, zero molten flaming droplets permittedDirectly achieves M1 rating; organophosphorus comonomer suppresses melting and flaming dripsHeavy coatings may downgrade to M2/M3 due to smoke or droplet releaseFrench/Belgian hospitality, embassy, university, and high-rise office specifications
BS 5867-2 Type B & Type C (United Kingdom)BS EN ISO 15025 Surface Ignition + BS EN ISO 10528 Industrial WashType B: after 12 standard washes; Type C: after 50 commercial washes (75°C) with afterflame ≤ 2.5 secPasses both Type B and rigorous 50-wash healthcare Type C unconditionallyCan only pass Type B under Dry-Clean-Only restriction; fails 50-wash Type C hospital testUK & GCC hotels (Type B) and NHS / International Hospital cubicle & ward curtains (Type C)
NFPA 701 (USA & Global Hospitality Chains)Test Method 1 (<700 g/m² Drapery) & Method 2 (>700 g/m² Vinyl/Blackout)Afterflame ≤ 2.0 sec, mass loss ≤ 40%, flaming residue on floor ≤ 2.0 secPermanent compliance under both Method 1 (Sheers, Dimout, Drapery) and Method 2 (Stage/Blackout)Applied via FR-compounded acrylic/PU foam in 3-Pass blackout and roller shade fabricsMarriott, Hilton, Hyatt, IHG brand standards and US Embassy / diplomatic facilities
IMO FTP Code Part 7 & EN 13501-1 (Marine & Building)IMO Res. A.471(XII) & Euroclass B-s1,d0 / B-s2,d0Marine suspended textile flame/smoke test; EN 13501-1 s1=minimal smoke, d0=zero flaming dropletsIMO Wheelmark & Euroclass B-s1,d0 certified for cruise ships, superyachts, and high-rise facadesRestricted in enclosed marine cabins due to higher smoke density (s2/s3)Superyachts, cruise liners, airport terminals, and high-rise commercial towers
Blackout (100%), Dimout (92%–98%), Solar Screen (1%–10% OF) & Duet Honeycomb Thermal Specification ☀️ 3. Blackout, Dimout & Screen Optical
TS EN 14501 • EN 410 • ISO 9050 • AATCC TM203 (0 Lux) • Screen OF %1–%10 • Duet Honeycomb

Blackout (100%), Dimout (92%–98%), Solar Screen (1%–10% OF) & Duet Honeycomb Thermal Specification

Optical, UV, and solar thermal performance matrix under EN 14501, EN 410, and AATCC TM203 for 3-Pass Blackout (0 Lux), Triple-Weave Dimout, Fiberglass/PES Screen blinds, Exterior Zip Screens, and Cellular Honeycomb shades.

  • ✓Optical distinction between 3-Pass Coated Blackout (100% / 0 Lux) and Triple-Weave Dimout (92%–98%)
  • ✓Solar Screen Openness Factors (1%, 3%, 5%, 10% OF) and Exterior Zip Screen (EN 13561 Wind Class 3–6)
  • ✓Up to 46% thermal heat-loss reduction (ΔU) with foil-lined Duet Honeycomb cellular shades
🔍 Toggle Quick Table Preview (6 rows)
Optical / Thermal Fabric ClassWeaving & Coating TechnologyWeight (GSM) & ThicknessVisible Light Transmittance (Tv) & OpacitySolar Factor (gtot / SHGC) & UV BlockageAcoustic & Physical BehaviorArchitectural Use & Installation Rule
100% Total Blackout (3-Pass Coated Drapery & Roller)Woven PES base with 3-layer (White + Black + White) acrylic/polyurethane dispersion foam coating280 – 440 g/m² (0.45 – 0.65 mm)100% Light Blockage (Tv = 0.00%; zero lux leakage under 100,000 Lux — AATCC TM203)Reduces solar heat gain by 35%–45%; cuts winter window heat loss (U-value) by 24%; 100% UV blockCrisp, structured hand; needle stitch holes can leak pinpoint light if unsealedHotel guestrooms, home theaters, projection rooms • Requires +10/30 cm wall overlap or aluminum side U-channels
100% Blackout Membrane-Laminated Drapery (3-Ply Textile)Decorative linen/velvet/jacquard face + internal black PU membrane + soft backing scrim340 – 520 g/m² (0.70 – 1.10 mm)100% Light Blockage (Tv = 0.00%)Superior thermal insulation (gtot ≤ 0.28) and condensation resistanceSupple S-Wave drape compared to foam coatings plus high sound absorption (αw ≈ 0.65)5-Star hotel suites, luxury master bedrooms, and VIP projects without separate lining
85%–98% Room Darkening (Triple-Weave Dimout Drapery)Chemical-free 3-ply weave integrating high-density black weft/warp yarn sandwiched between two decorative faces220 – 350 g/m² (0.40 – 0.55 mm)92%–98% light reduction in dark tones; 80%–88% in ivory/beige tones (Tv = 2% – 15%)Reduces solar heat gain by 30%–40%; 95%+ UV blockageFluid S-Wave drape, breathable, machine washable at 30°C, zero coating peel or crackingResidential bedrooms, studies, hospital rooms • Pair with blackout lining if 100% pitch darkness is required
Solar Screen Roller Shade (1% – 3% Openness Factor)30% Polyester + 70% PVC-coated yarn or 36% Fiberglass + 64% PVC basketweave410 – 540 g/m² (0.55 – 0.75 mm)Visible transmittance Tv = 1% – 3%; eliminates 97% of monitor glareEN 14501 Indoor gtot = 0.32 – 0.42; Exterior Zip Screen gtot = 0.08 – 0.14; 97%–99% UV blockZero sag/stretch dimensional stability; preserves daytime view out while blocking view inSouth/West commercial glass facades, executive offices • Combine with drapery for nighttime privacy when indoor lights are on
Solar Screen Roller Shade (5% – 10% Openness Factor)30% PES + 70% PVC or Trevira CS (100% Halogen-Free IFR Screen)360 – 450 g/m² (0.45 – 0.60 mm)Visible transmittance Tv = 5% – 10%; abundant natural daylight and clear outward panoramaEN 14501 gtot = 0.43 – 0.52; 90%–95% UV blockageUltrasonic sealed edges prevent fraying; antistatic dust-repellent finishNorth/East offices, restaurants, hotel lobbies, and panoramic living rooms
Duette Honeycomb Cellular Pleated Shade (Translucent & Blackout)Hexagonal double-wall air-pocket spunbond/woven polyester; blackout version features internal aluminum foil160 – 240 g/m² (20 mm / 25 mm cell size)65% light filtering in translucent; 99%–100% blackout in foil-lined Duette (zero visible cord holes)Cellular air pockets reduce glazed balcony and skylight heat loss by up to 46%Concealed internal lift cords; Top-Down / Bottom-Up dual operationFolding glass balconies, winter gardens, skylights, and tilt-and-turn windows
Textile Chemical Finishes (Water/Stain Repellency), UV Lightfastness, Martindale & Ecology Standards 🧪 4. Finishes, Fastness & Ecology
EN ISO 4920 • ISO 14419 • DIN EN ISO 105-B02 • ISO 12947-2 Martindale • ISO 20743 Ag+ • OEKO-TEX 100

Textile Chemical Finishes (Water/Stain Repellency), UV Lightfastness, Martindale & Ecology Standards

Comprehensive textile chemistry and durability specification: EN ISO 4920 Water Repellency, ISO 14419 Oil/Stain Resistance, DIN EN ISO 105-B02 UV Lightfastness, ISO 12947-2 Martindale Abrasion, ISO 20743 Silver-Ion Antibacterial, and OEKO-TEX Standard 100 / GREENGUARD Gold.

  • ✓Hydrophobic & Oleophobic Finishes: EN ISO 4920 (Grade 4–5) & ISO 14419 (C6 Fluorocarbon / PFAS-Free)
  • ✓UV Fade Resistance: DIN EN ISO 105-B02 Blue Wool Scale (Grade 5–7+) & Heat-Set Shrinkage (±1.0%)
  • ✓Healthcare Hygiene (ISO 20743 Ag+ >99% bacterial reduction) & OEKO-TEX 100 / GREENGUARD Gold
🔍 Toggle Quick Table Preview (7 rows)
Performance & Finish CategoryInternational Standard CodeScale & Test MethodologyResidential ThresholdHotel / Healthcare / Contract ThresholdChemical / Mechanical Finishing Technology & Engineering Note
Colorfastness to Artificial Light (UV Fade Resistance)DIN EN ISO 105-B02 (US: AATCC TM16.3 Xenon Arc)Blue Wool Scale (1 = Very Poor to 8 = Outstanding; each grade doubles fade resistance)Category B: Min. Grade 4–5 (Standard indoor)Category A: Min. Grade 6 – 7+ (Mandatory for South facades, winter gardens & hotels)Disperse/Vat dyeing + UV-absorber finish; dark natural linen/cotton drapery requires protective lining against direct sun
Water, Oil & Stain Repellency (Hydrophobic / Oleophobic Finish)EN ISO 4920 (Spray Test) & ISO 14419 (Oil Repellency)ISO 4920: Grade 1–5 (or AATCC 22: 0–100); ISO 14419: Grade 1–8 hydrocarbon drop scaleISO 4 (80 points) — Liquid beads off surface (Lotus effect)ISO 5 (90–100 points) Water Repellency + Grade 5–6 Oil/Coffee RepellencyC6 Fluorocarbon / Teflon® or PFC-Free dendrimer finish; prevents kitchen grease and moisture penetration on roller & pleated blinds
Washing Fastness, Crocking & Dimensional Stability (Sanforizing)ISO 105-C06 (Washing) • ISO 105-X12 (Rubbing) • ISO 6330 / ISO 5077 (Shrinkage)Grey Scale 1–5 (Color change & staining); Warp/Weft shrinkage percentage (%) after washingFastness: Grade 4 • Shrinkage: PES ≤ 1.5%, Natural Linen/Cotton ≤ 3%–5%Fastness: Grade 4–5 • Shrinkage: Heat-Set PES ≤ 1.0%190–210°C Stenter heat-setting and mechanical Sanforizing (steam compression) eliminate post-wash hem shortening
Abrasion Resistance (Martindale), Pilling & Seam SlippageISO 12947-2 (Martindale) • ISO 12945-2 (Pilling) • ISO 13936-1/2 (Seam Slippage)Martindale: Rub cycles until 2 yarn breaks; Pilling: Grade 1–5; Seam opening: mmDrapery: 10,000–15,000 rubs • Residential Upholstery: 20,000–25,000 rubs • Pilling ≥ 4Heavy Contract / Hotel Lobby: 40,000 – 100,000+ rubs • Seam slippage ≤ 4 mm (@ 60N/180N)Honest Engineering Rule: ISO 12947-2 is the test method; the required rub count (e.g. 40,000) is the buyer specification threshold
Antibacterial, Antifungal & Hospital Cubicle Hygiene StandardISO 20743 (Antibacterial Activity) • AATCC 100 / ASTM E2149 • ISO 13688Logarithmic reduction of Staphylococcus aureus (MRSA) & Klebsiella pneumoniae over 24hAntistatic dust-repellent finish (EN 1149)≥ 99.0% bacterial reduction (Log ≥ 2.0–3.0) + Top 50 cm fire-sprinkler Mesh HeaderSilver-ion (Ag+) or quaternary ammonium antimicrobial finish; hospital cubicle curtains include top 50 cm 70%-open mesh for sprinkler water flow
Acoustic Sound Absorption (Reverberation Control)TS EN ISO 354 (Reverberation Room) • EN ISO 11654 (αw Rating) • ISO 9053-1 (Airflow Resistance)Weighted Sound Absorption Coefficient αw (0.00 – 1.00) & Acoustic Class A, B, C, D, EStandard drapery (1:2 fullness): αw = 0.35 – 0.50 (Class D)Acoustic Velvet / Multi-Layer Contract Drapery (1:2.5 fullness, 10–15 cm from glass): αw = 0.65 – 0.90 (Class A–B)Specific airflow resistance Rs = 500–1500 Pa·s/m and ≥350 g/m² porous weave; eliminates echo in boardrooms, auditoriums & home cinemas
Human Ecology, Toxicology & Digital Product PassportOEKO-TEX® Standard 100 • REACH (EC 1907/2006) • GRS / GOTS • EU ESPR (DPP)Testing for 100+ regulated substances, carcinogenic AZO dyes, formaldehyde, heavy metals & phthalatesOEKO-TEX Class IV (Home Furnishing) or Class IIOEKO-TEX Class I (Baby/Nursery) & Class II/IV + Lead-Free stainless hem weight bandAll Ardıç Curtain fabrics are 100% AZO-free and formaldehyde-free, ensuring safe indoor air quality in nurseries and clinics
Curtain Product Groups, Yarn Count (Denier/dtex), Weave Density, GSM & Pleat Sewing Engineering 🧵 5. Curtain Groups, Weaving & Sewing
TS EN ISO 2060 (Denye/dtex) • TS EN 1049-2 • ISO 3801 (GSM) • 300 cm Eksiz En • S-Wave & Kanun Pile

Curtain Product Groups, Yarn Count (Denier/dtex), Weave Density, GSM & Pleat Sewing Engineering

Complete textile and atelier tailoring specification for Voile, Linen/PES Slub, Velvet, Satin, Blackout, Dimout, Roller, Zebra, Plisse, and Vertical blinds: yarn denier/dtex, warp/weft density, GSM, 300 cm seamless width, and S-Wave / Pinch Pleat fullness ratios.

  • ✓Honest fiber disclosure: Micro-Voile (50D×50D), PES Slub ('Linen-Look' wrinkle-free) vs. 100% Natural Flax Linen
  • ✓S-Wave Ripplefold (60mm/80mm cord pitch, even glider rule) & 1:3 Triple Pinch/Box Pleat atelier standards
  • ✓300–320 cm seamless room-high fabric width, 10 cm double bottom hems, and 50–100 g/m lead weight cord
🔍 Toggle Quick Table Preview (5 rows)
Curtain Group & Fabric TypeWeaving / Knitting Structure & Yarn CountStandard Weight (GSM) & Roll WidthRecommended Fullness Ratio & HeadingBottom Hem & Side Hem Tailoring StandardEngineering & Maintenance Rule
S-Wave Linen-Textured Sheer (100% PES Slub vs. Natural Flax Linen)Open plain/panama weave; 75D–150D slub textured polyester filament/staple or Nm 20–36 natural flax85 – 145 g/m² • 300 – 320 cm Seamless Width (Railroaded)S-Wave (1:2.0 – 1:2.33 fullness; 6 cm or 8 cm glider cord pitch, even glider count symmetry rule)Bottom hem: 50–70 g/m braided weight cord (Bleiband) or 5×5 cm double-turned hemHonest Rule: 90% of 'Linen Sheers' in the market are wrinkle-free 100% PES Slub; 100% natural flax expands/shrinks 3%–5% with ambient humidity
Silk Voile, Organza, Grecian Honeycomb & Raschel Lace SheersVoile: High-twist (800–1200 T/m) 50D–75D plain weave; Grecian: 3–6 mm dobby honeycomb; Raschel: Warp-knitVoile/Organza: 40–80 g/m² • Grecian/Raschel: 70–120 g/m² • 300 cm Width1:2.5 Medium Pleat or 1:3.0 Triple Pinch / Box Pleat (Iron-free recovery)Factory weighted hem cord (50–70 g/m) + 2 cm blind-stitched side hemsGrecian and Raschel warp-knit sheers offer maximum air permeability and snag-resistant wrinkle recovery
Silk Velvet, Satin, Jacquard & Chenille Decorative DraperyVelvet: Warp-pile (W/V-weave) 1.5–2.5 mm pile height; Satin: 5/8-harness warp satin; Jacquard: Multi-weftSatin: 200–300 g/m² • Jacquard: 250–400 g/m² • Velvet: 320–500 g/m² (140 cm or 300 cm width)S-Wave (1:2.2) or 1:2.5 – 1:3.0 Flemish Pinch Pleat • Min. 50 cm side dress panel widthBottom hem: 10×10 cm (20 cm allowance) double-fold blind stitch + 25 g corner weights • Side hem: 2.5–3 cm double foldAll velvet panels must be cut in the identical pile direction (nap down) to prevent optical color shading
Roller & Zebra (Day-Night) Mechanical Blind FabricsRoller: Acrylic/PVA stiffened plain-weave PES; Zebra: Dual-layer 7–10 cm opaque + 5–7 cm sheer mesh stripesRoller: 190–320 g/m² • Zebra: 140–240 g/m² (Bamboo/Linen/Blackout) • 200–300 cm Width1:1 Flat Roll (Ø 32 mm, 38 mm, or 50 mm reinforced extruded aluminum tube)Ultrasonic laser-sealed edges (zero fraying) + Anodized or fabric-wrapped aluminum bottom barCalendering and stiffening finish prevent edge cupping and telescoping during vertical tube winding
Roman Shades, Japanese Panel Blinds & Cafe CurtainsRoman: 150–280 g/m² linen/sheer/dimout; Japanese Panel: 60–90 cm wide stiffened flat vertical panels120 – 300 g/m² • 280 – 300 cm WidthRoman 1:1 flat width + 4 mm fiberglass rod tunnels every 25–30 cm + weighted bottom barVelcro aluminum headrail with 1:4 geared endless bead chain or tubular motorAdjacent windows of varying heights align rod tunnels to the shortest window module; rear-ring sewing hides front stitch lines
Motorized Curtain Systems (Torque Nm / dBA), Smart Home Automation (KNX/Matter), Acoustics (ISO 354) & Child Safety ⚡ 6. Motors, Automation & Acoustics
EN IEC 60335-2-97 • Somfy Sonesse / Glydea (<30–38 dBA) • KNX / Matter / Zigbee • TS EN ISO 354 • EN 13120

Motorized Curtain Systems (Torque Nm / dBA), Smart Home Automation (KNX/Matter), Acoustics (ISO 354) & Child Safety

Engineering specification for EN IEC 60335-2-97 tubular and drapery track motors (Somfy Sonesse / Glydea), torque sizing, <30–38 dBA acoustic rating, KNX / DALI / Matter / Zigbee 3.0 / Dry-Contact BMS integration, ISO 354 sound absorption, and EN 13120 child safety.

  • ✓Brushless DC Drapery Track Motors (35–100 kg, Touch Motion) & Tubular Motors (0.55–50 Nm, <30–38 dBA)
  • ✓Native BMS & Smart Home integration: KNX, DALI, RS485, Dry-Contact, Matter over Thread, Zigbee 3.0 & RTS/io
  • ✓ISO 354 Acoustic Sound Absorption (αw 0.55–0.85, Class A/B) & Mandatory EN 13120 Child Safety Compliance
🔍 Toggle Quick Table Preview (5 rows)
Motor & Automation GroupTorque (Nm) / Load CapacityAcoustic Noise Level (dBA)Power Supply & Linear SpeedSmart Home & BMS ProtocolElectrical / Mechanical & Child Safety StandardEngineering Formula & Application Feature
Ultra-Quiet Motorized Drapery Track (Standard Residential/Hotel)0.6 Nm — Max 35 kg Curtain Load (Up to 10 m straight track)≤ 38 dBA (Silent bedroom and hotel guestroom standard)230V AC 50Hz or 12V Li-ion Rechargeable Battery (1–2 charges/year) • 12–16 cm/sRF 433.42 MHz (RTS) / 868 MHz (io), Zigbee 3.0, Matter over Thread, Wi-FiEN IEC 60335-2-97 • IP30 Indoor • CE & RoHSTouch Motion (gently pull fabric 5 cm to trigger motor), Soft Start / Soft Stop, manual override during power outage
Heavy-Duty Architectural & Stage Drapery Track Motor1.0 – 1.2 Nm — Max 60 kg (Up to 100–120 kg in Tandem dual-motor; 12–15 m track)< 30 – 35 dBA (Whisper-quiet brushless DC motor)230V AC 50Hz or 24V DC • Adjustable speed: 12.5 – 20 cm/sKNX, DALI, RS485, Dry-Contact, Zigbee 3.0, Apple Home / Google / AlexaEN IEC 60335-2-97 • Electromagnetic brake & overload protectionDeduct 15%–20% load capacity per 90° or curved bend for friction; mandatory for double-height atriums & auditoriums
Compact Tubular Motor — Ø 28mm / 30mm / 35mm0.55 Nm (≤ 5 m²) • 1.1 Nm (≤ 10 m²) • 2.0 Nm (≤ 18 m² roller/zebra/pleated)30 – 38 dBA (Sonesse / Silent Architectural Series)24V DC, 12V Built-in Li-ion WireFree (Zero wall wiring) or Solar Panel • 10–28 rpmZigbee 3.0 (0%–100% bi-directional position feedback), Thread, RF RemoteEN IEC 60335-2-97 • Electronic upper/lower limits & obstacle detectionTorque Formula: T (Nm) = [Fabric Weight (kg) + Bottom Bar (kg)] × 9.81 × Tube Radius r (m) × 1.35 (Safety Factor)
High-Torque Tubular Motor — Ø 40mm / 45mm / 50mm+4 Nm (≤ 12 kg) • 6 Nm (≤ 18 kg) • 10–15 Nm (≤ 30–45 kg heavy 50mm wood blinds & facade screens)38 – 44 dBA230V AC 50Hz • 12 – 17 rpm • Thermal cut-off protectionRTS / io-homecontrol, KNX, Wind (Anemometer) & Sun (Lux) Sensor AutomationIndoor: IP30–IP44 • Exterior Zip Screen & Winter Garden: IP44 – IP55 weatherproofSynchronizes both slat tilt and full lift on heavy 50mm Wood (White, Walnut, Mahogany, Oak, Grey, Black) blinds (>4.8 m²) with millimetric precision
Child Safety & Mechanical Control StandardBreakaway chain/cord connector: releases automatically at ≤ 6 kg loadSilent geared clutch mechanismManual Bead Chain, Spring-Assist, or 100% Cordless / MotorizedMechanical safety complianceTS EN 13120:2009+A1:2014 + EN 16433 + EN 16434 (EU Decision 2011/477/EU)For 0–42 month child safety, all chain loops must be anchored ≥ 150 cm above floor via wall tension pulley or replaced by cordless motorization
Architectural Aluminum Tracks (6063-T5), Stainless/Brass Rods, Roller Tubes & Hardware Specification 🔩 7. Tracks, Rods, Tubes & Hardware
EN AW-6063 T5/T6 • AISI 304 rods • POM (Delrin) 11 kg gliders • Deflection ≤ L/500 • Lead hem weight

Architectural Aluminum Tracks (6063-T5), Stainless/Brass Rods, Roller Tubes & Hardware Specification

Complete mechanical hardware specification: EN AW-6063 T5/T6 extruded aluminum tracks (1.2–2.2 mm wall thickness, 6.0 mm MAXI channel), AISI 304 stainless & solid brass drapery rods, UV-stabilized POM (Delrin) 11 kg gliders, ball-bearing S-Wave carriers, Ø38–50mm roller tubes (deflection ≤ L/500), and bottom hem weights.

  • ✓EN AW-6063 T5/T6 Extruded Aluminum Tracks (1.4–2.2 mm wall, 6.0 mm MAXI channel, Qualicoat / Anodized)
  • ✓UV-stabilized Polyacetal (POM / Delrin) gliders (11 kg static load rating) & stainless ball-bearing S-Wave carriers
  • ✓Ø38mm / Ø45mm / Ø50mm keyway-reinforced aluminum roller tubes (Deflection ≤ L/500) & 50–100 g/m hem weight cords
🔍 Toggle Quick Table Preview (5 rows)
Hardware & Accessory ComponentAlloy & Raw Material StandardProfile Cross-Section & CoatingStatic Load & Tensile CapacityBracket Spacing & Mounting RuleArchitectural Advantage & Specification Detail
Heavy-Duty Architectural Aluminum Track & Recessed Profile (VS57)EN AW-6063 T5 / T6 Extruded Aluminum Alloy (DIN EN 573-3 / EN 755-2)1.2 – 1.8 mm wall thickness • 6.0 – 6.6 mm MAXI slot width • 15–20 μm Powder Coated / Anodized7 – 8 kg / linear meter (6m seamless lengths; CNC bendable to 90° and bay curves)Steel ceiling bracket every 50 – 60 cm; 30 cm spacing in curtain stack-back zoneNever yellows, sags, or jams like plastic PVC tracks; installs flush into drywall ceiling coves
Low-Friction Glider (Rulet), S-Wave Pitch Cord & Microflex HookUV-Stabilized Polyacetal (POM / Delrin) Body + AISI 304 Stainless Steel Axle/HookMAXI 6.0 mm slot Click-In (Clic) & Ball-Bearing gliders; 6 cm / 8 cm S-Wave cord spacingSingle glider static load rating: 11 kg (12–16 gliders/m = >100 kg safety margin)Snap-in insertion anywhere along the track channel; stainless screw-lock end stopsUltra-low friction; gliders are machine-washable (30–40°C in mesh bag) without removal; Microflex hooks allow ±2.5 cm height tuning
Decorative Curtain Rods (Solid Brass, Antique Bronze, Stainless & Wood)Solid Brass (CuZn37), AISI 304 Stainless, Matte Black Aluminum, Kiln-Dried Hornbeam/Wood (White, Walnut, Mahogany, Oak, Grey, Black)Tube Diameter: Ø 19 mm (Sheer), Ø 28 mm (Standard Drapery), Ø 35 mm (Heavy Velvet) • Ringed or Internal Track6 – 8 kg / linear meter (Teflon-lined silent rings or Ø 40 mm stainless eyelets)≤ 140 cm: 2 Brackets • 140–280 cm: 3 Brackets (Center support mandatory) • > 280 cm: 4 Brackets • Steel Molly anchors on drywallInner-tracked decorative rods allow S-Wave sheers and drapery to glide past center brackets without ring obstruction
Roller / Zebra Winding Tube, Geared Clutch & Exterior ZIP Channel6063-T5 Reinforced Aluminum Tube + Glass-Fiber Reinforced Polyamide (PA66 + 30% GF) ClutchTube Diameter: Ø 32 mm (≤ 180 cm width), Ø 38 mm (180–240 cm), Ø 50 mm+ (240–350 cm anti-deflection)1:4 Reduction heavy-duty clutch + Stainless steel or POM bead chainAdjacent roller blinds have a 3.0 – 3.5 cm bracket light gap that must be aligned with window mullionsExterior ZIP Screen welds a zipper along fabric edges locked inside side channels; rated to EN 13561 Wind Class 3 (90–120 km/h)
Drapery Draw Rod (Baton / Schleuderstab), Holdbacks & Hem WeightsClear Acrylic (PMMA / Plexiglas) or Anodized Aluminum Baton + Stainless/Lead Hem CordDraw Rod: 100 – 150 cm length, Ø 10–12 mm with snap hook • Hem Cord: 50 g/m, 70 g/m, 100 g/mProtects fabric from hand oils and header tearing; hem weights prevent billowing over HVAC ventsWall holdbacks (Renso/Ambrans) mount at 90 – 110 cm above finished floorMandatory in 5-star hotel specifications: attach draw baton to the master carrier so guests never pull directly on fabric edges
Curtain Motor Brands (Somfy, Becker, Silent Gliss, Mosel), Remote Pairing & Limit Programming Manual 🎮 8. Motor Brands & User Manual
Somfy • Becker • Silent Gliss • Forest • Mottura • Nice • Mosel • Remote pairing & limit guide

Curtain Motor Brands (Somfy, Becker, Silent Gliss, Mosel), Remote Pairing & Limit Programming Manual

Complete engineering comparison and step-by-step user manual for Somfy, Becker, Elero, Silent Gliss, Forest Shuttle, Mottura, Nice, Mosel, and Dooya curtain motors: PROG/P2 remote pairing, upper/lower limit setting, battery charging, and factory reset.

  • ✓Head-to-head comparison: Somfy (France), Becker (Germany), Silent Gliss (Switzerland), Forest, Nice/Mottura & Mosel
  • ✓Step-by-step Remote Pairing (PROG / P2), Direction Reversal & Upper/Lower End-Limit Programming
  • ✓WireFree Lithium-Ion battery care rules and 3-Jog Factory Reset procedure
🔍 Toggle Quick Table Preview (5 rows)
Motor Brand & OriginFlagship Models & TypesTorque (Nm) / Load & Noise (dBA)Remote Pairing (PROG) & Limit Setting SummaryMaintenance, Battery & Factory Reset Rule
Somfy (France — Global Leader)Sonesse 30/40 RTS & io, Sonesse Ultra 50, Glydea Ultra 35e/60e, Movelite 35, Tilt & Lift 25, WireFree Li-Ion0.8–50 Nm (Tube) / 35–100 kg (Track) • <30–38 dBAHold motor PROG button 2s (1 jog) -> press remote rear PROG 1s. Hold Up+Down together to set limits; save with MY button.Recharge WireFree Li-Ion every 6–9 months (4.5h charge). Factory reset: hold motor PROG for 3 jogs (12s).
Becker & Elero (Germany)Becker R8/R12/E14, Elero RolTop / VariEco (Roller, Exterior Zip & Conservatory Motors)5–40 Nm • 39–43 dBA • German Mechanical & Electronic LimitsAdjust mechanical Allen screws (+ / -) on motor head or program electronic end-limits via Master transmitter.Keep obstacle & ice detection active on exterior Zip screens; wipe side zip channels annually.
Silent Gliss (Switzerland) & Forest Shuttle (Netherlands)Silent Gliss 5600/5100, Forest Shuttle L/M/S (Luxury Hotel, Embassy & Yacht Drapery Tracks)40–120 kg Load • <32 dBA Whisper Quiet • Touch-MotionPull curtain 5 cm by hand to trigger Touch-Motion. Automatically calibrates left/right end stops on first power-up.Features Emergency Declutch for manual operation during power outages. Lubricate track only with dry PTFE silicone spray.
Mottura & Nice / Cherubini (Italy)Mottura Futuro / Power 571 (Stage & Heavy Velvet), Nice Era Mat / Era Inn Edge, Cherubini Blue Tronic3–50 Nm / up to 80 kg Stage Drapery • 36–42 dBAEnter programming mode via PRG button or double power-cycle; lock upper/lower limits with directional arrows.Inspect steel-core toothed drive belt tension every 2 years on stage and auditorium tracks.
Mosel & Novo / Dooya / Brel (Project & Residential Value)Mosel DM25 (Battery/DC), DM35R (Roller/Zebra/Wood Blind), DM45R (Zip), Dooya DT52E / DT82TV (Track)1.1–50 Nm (Tube) / 45–60 kg (Track) • 38–44 dBAPress 'P2' twice on remote back -> press 'Up' to pair. Hold motor button 5s to reverse roll direction if needed.5-year warranty for residential and office projects. Group up to 15 blinds on a single multi-channel remote.
Master Curtain Care Guide: Washing, Ironing, Stain Removal & Hardware Maintenance Specification 🧼 9. Curtain Care, Washing & Maintenance
ISO 3758 care labels • 30°C / 400 rpm rule • Blackout, velvet, wood blind & roller cleaning • PTFE track care

Master Curtain Care Guide: Washing, Ironing, Stain Removal & Hardware Maintenance Specification

Professional care and maintenance manual for Voile/Linen Sheers, 3-Pass Blackout vs. Dimout, Velvet, 50mm Basswood Venetian Blinds, Roller/Zebra Shades, Plisse Shades, and Aluminum Tracks (ISO 3758).

  • ✓Wrinkle-Free Sheer Formula: 30°C delicate wash inside a mesh bag, max 400 RPM spin, and hang damp directly on the track
  • ✓Critical cleaning difference between 3-Pass Foam-Coated Blackout (wipe/dry-clean) and Woven Dimout (30°C washable)
  • ✓Basswood Venetian, Roller/Zebra, Plisse cleaning rules & dry PTFE silicone spray track lubrication
🔍 Toggle Quick Table Preview (6 rows)
Curtain Group & Fabric TypeWashing Temp, Spin & Method (ISO 3758)Drying & Ironing TechniqueCritical Mistakes to AvoidAnnual Hardware & Track Maintenance Tip
Sheer Curtains (Voile, PES Slub Linen, Guipure, S-Wave)30°C Delicate Cycle • Max 400 RPM Spin (or No Spin) • Wash inside a Mesh Laundry Bag with gliders attached; no optical bleachHang damp directly onto the track immediately after washing; the bottom lead weight cord pulls creases out naturally without ironing.Hot water (>40°C), high spin (>800 RPM), and chlorine bleach break heat-set fibers and cause permanent creasing.Wipe aluminum track channel annually and apply dry PTFE silicone spray (never use liquid oil or WD-40).
3-Pass Coated Blackout vs. Triple-Weave Dimout Drapery3-Pass Coated Blackout: Dry Clean Only or Damp Microfiber Wipe • Triple-Weave Dimout: Machine Washable at 30°C / 400 RPMHang Dimout damp or iron face side at low heat (110°C). Never touch a hot iron to the white acrylic foam back of 3-Pass Blackout!Machine spinning 3-Pass foam-coated blackout causes the acrylic layers to stick together and peel (pinhole light leaks).Check track end-stops and S-Wave cord snap carriers once a year on heavy blackout drapery.
Silk Velvet, Chenille & 100% Natural Flax Linen DraperyProfessional Dry Cleaning Only (Perchloroethylene — P Symbol) • Routine care: vacuum downward using a soft brush attachmentSteam vertically while hanging using a garment steamer held 5 cm away in the direction of the pile.Wet-washing 100% natural linen causes 4%–6% shrinkage; flat-ironing velvet crushes the pile and leaves permanent shiny marks.Rotate tieback positions slightly during summer months to equalize sun exposure along the leading edge.
50mm & 25mm Kiln-Dried Wood (White, Walnut, Mahogany, Oak, Grey, Black) & Polymer Venetian BlindsNatural Wood: Never wash with water! Dust with ostrich feather duster or barely damp cloth • Polymer (Faux-Wood): Washable with mild soapClose slats flat to wipe the front face, then tilt 180° to wipe the back face parallel to the wood grain.Hosing down natural Wood (White, Walnut, Mahogany, Oak, Grey, Black) blinds or using steam cleaners cracks the UV lacquer and warps timber slats.Apply a light natural beeswax/wood conditioner every 2 years to preserve timber luster.
Roller, Zebra, Sheer Roller & Solar Screen BlindsNever put in a washing machine! Wipe flat on a clean surface with neutral-pH foam or use Ultrasonic Blind CleaningNever roll up while wet (prevents mildew); leave fully lowered to dry at room temperature.Folding or scrubbing roller fabric breaks the acrylic stiffener finish, causing frayed edges and V-rippling.Pull bead chains vertically (90° straight down) rather than at an angle to extend clutch gear life beyond 10 years.
Plisse (Balcony) & Duet Honeycomb Cellular ShadesSoak for 15 min in a 30°C lukewarm mild soap bath (keep aluminum profiles out of water) and rinse with a gentle shower headCompress the blind into a tight closed stack while wet, squeeze out excess water by hand, reinstall, and dry partially stacked.Drying a Plisse shade fully extended while wet relaxes the 20mm heat-set accordion pleat memory.Check bottom shoe spring tension annually on glass-balcony plisse cords; keep bleach away from tension cords.
ENGINEERING FORMULAS & HONEST SPECIFICATION RULES (AEO / GEO / MCP)

Architectural Curtain Calculation Formulas & 6 Golden Engineering Rules

1. Fabric Yardage, Fullness Ratio & S-Wave Even Glider Rule

Width Formula: Cut Width = (Track Width × Fullness Ratio) + (2 × 6 cm Side Hems). Specify 1:2.0 – 1:2.33 for S-Wave and 1:2.8 – 1:3.35 for Triple Pinch Pleat. S-Wave panels require an even number of gliders per panel (e.g. 14, 16, 18) so both leading and trailing edges return cleanly toward the wall.

2. Motor Torque (Nm) & Curtain Weight Formula

Curtain Weight (kg): Width (m) × Fullness × Drop (m) × (Fabric GSM + Lining GSM) / 1000.
Tubular Motor Torque: T (Nm) = [Fabric Weight (kg) + Bottom Bar (kg)] × 9.81 × Tube Radius r (m) × 1.35 (Safety Factor). Deduct 15%–20% capacity per 90° track bend.

3. Inherently Flame Retardant (IFR) ≠ Topical FR Rule

Critical Tender Distinction: IFR (Trevira CS / phosphorus-modified polyester) locks fire retardancy inside the molecular chain permanently—passing BS 5867-2 Type C (50 commercial washes), DIN 4102-B1, EN 13773 Class 1 & NFPA 701 for life. Topical FR chemical dips leach out after 5–10 wet washes.

4. 3-Pass Blackout vs. Triple-Weave Dimout Distinction

Optical Honesty: 3-Pass Coated / Membrane Blackout achieves 100% (0 Lux) total darkness (AATCC TM203). Uncoated Triple-Weave Dimout offers fluid drape and washability with 92%–98% light reduction in dark tones and 80%–88% in light tones; add blackout lining if pitch darkness is required.

5. Golden Ratio Side Drapery & -2 cm Floor Clearance

Architectural Proportion: Stationary side dress panels must finish at least 50 cm wide (70–90 cm on wide facades), positioned 60% on the wall and 40% over the glass. Deduct -1.5 to -2.0 cm from ceiling-to-floor drop for robot vacuum clearance, and finish inner sheers -0.5 cm shorter than drapery.

6. 6 Critical Checkpoints for Mechanical Blind Orders

Production Verification: (1) Measurement type: Total Bracket Width vs. Exact Fabric Width (3.0–3.5 cm delta), (2) Roll direction: Standard vs. Reverse Roll, (3) Chain side & EN 13120 child safety height (≥150 cm above floor), (4) Ceiling clip vs. Wall L-bracket, (5) Aligning 3.5 cm multi-blind gap with window mullions, (6) Mandatory 100% Waterproof Polymer Venetian in wet zones.

AI SEARCH (AEO / GEO / MCP) & TENDER TECHNICAL FAQ LIBRARY

Frequently Asked Engineering Questions on Curtain Standards, IFR/FR, Finishes, Motors & Hardware

What is the engineering difference between IFR (Inherently Flame Retardant) and FR chemically treated curtains? ▾

IFR (Inherently Flame Retardant / Trevira CS) fabrics integrate organophosphorus comonomers directly into the polyester polymer chain, retaining 100% of their flame retardancy permanently across 50+ industrial washes (BS 5867-2 Type C, DIN 4102-B1, EN 13773 Class 1, NF P 92-503 M1, NFPA 701). Chemically treated FR fabrics are dipped in topical flame-retardant salts after weaving, which dissolve after 5–10 wet washes.

What is the optical difference between 3-Pass Blackout and Triple-Weave Dimout fabrics? ▾

3-Pass Blackout fabrics apply three layers (White-Black-White) of acrylic/PU dispersion foam or membrane lamination to block 100% of light (0 Lux under AATCC TM203). Triple-Weave Dimout fabrics contain no chemical coating, weaving a dense black core yarn between two decorative faces to block 92%–98% light in dark colors and 80%–88% in light colors while remaining breathable and washable.

Which ISO standards govern water repellency, stain resistance, and UV lightfastness in curtains? ▾

Water repellency (fluorocarbon / Teflon finish) is tested under EN ISO 4920 (Grade 1–5 spray test; contract threshold ISO 4–5), and oil/stain repellency under ISO 14419. UV fade resistance (lightfastness) is measured via DIN EN ISO 105-B02 Blue Wool Scale (1–8), requiring Grade 5+ for residential and Grade 6–7+ for south-facing hotel and conservatory facades.

What is the stack height of 50mm Wood (White, Walnut, Mahogany, Oak, Grey, Black) & Faux-Wood Venetian blinds, and can they be used in bathrooms? ▾

A 50mm 50mm Wood Venetian blind (White, Walnut, Mahogany, Oak, Grey, Black) has a stack height of 17 cm at 150 cm drop and 25 cm at 250 cm drop (including headrail). In bathrooms, over kitchen sinks, and humid winter gardens, natural wood must be replaced with 100% waterproof 50mm Polymer (Faux-Wood) or Aluminum Venetian blinds to prevent warping.

How are motorized curtain torque (Nm), noise rating (dBA), and smart home protocols specified? ▾

Motorized drapery tracks use 0.6 Nm (up to 35 kg) or 1.0–1.2 Nm (up to 60 kg) brushless DC motors operating below 30–38 dBA. Tubular motors for roller, zebra, and 50mm wood blinds comply with EN IEC 60335-2-97 (0.55 Nm to 15 Nm) and integrate natively with KNX, Matter over Thread, Zigbee 3.0, RTS/io, and Dry-Contact BMS systems.